It does not present official positions of the society nor reflect society policy. Documents ashrae 15 safety standard for refrigeration. Ansiashrae standard 552010 is the latest edition of standard 55. Ashrae standard 15 applied to packaged, split and vrf systems from the editor. Ashrae standards now available as online download offerings. This standard is applicable to singlefamily houses and multifamily structures of no more than three stories. Standards that are on continuous maintenance are continuously updated through addenda and ashrae makes these available free online. The 2010 edition of ansi ashrae standard 55 combines standard 552004 and the ten approved and published addenda to the 2004 edition into one easytouse, consolidated standard. Establishes safeguards for life, limb, health, and property and prescribes safety requirements. In a previous newsletter, we discussed the application of ansiashrae standard 15, safety standard for refrigeration systems, to large chillers and the machinery rooms that house them.
Standard 152019 packaged w standard 342019 safety standard for refrigeration systems and designation. Ashrae 15 erta safety standard for refrigeration systems. Nov 11, 2010 in order to move the industry forward toward more energy efficient design, ashrae is making it easier than ever before to access its flagship energy standard, 90. Pc may be available for direct download or for purchase through the ashrae bookstore, as noted below. The following links are to online readonly versions of these standards. Ashrae 15 safety standard for refrigeration systems, 2010. Ansi ashrae 15 2010 and ansi ashrae 34 2010 package safety standard for refrigeration systems.
Ashrae standard 15 the ashrae standard 15 2010 provides safeguards for life, limb, health, property, and prescribes safety requirements. The 2010 edition combines standard 552004 and the ten approved and published addenda to the 2004 edition into one easytouse, consolidated standard. This standard is directed toward the safety of persons and property on or near the premises where refrigeration facilities are located. Click on the following links to learn more about the free supplemental downloads available. The materials for this course may be used for inperson training purposes. Electric lighting directly consumes energy, but for airconditioned buildings, lighting als. Ashrae 15 20 highlights of whats new in the 20 edition. The standard outlines conditions in which a specified fraction of the occupants will find the envir onment thermally acceptable. The ashrae standard 152010 provides safeguards for life, limb, health, property, and prescribes safety requirements. The 2010 edition combines standard 552004 and the ten approved and published addenda to the 2004 edition into one easytouse, consolidat ed standard. Ashrae standard 15 2010 establishes safeguards for life, limb, health, and property and prescribes safety requirements. For easy access and application for codes and standards users, the international code council icc is collaborating with ashrae to make construction industry safety standards, as referenced in the 2012 international codes available to the building industry in a downloadable pdf format on the icc. Preface the 2010 ashrae handbookrefrigeration covers the refrig plus.
Addenda for ashrae standards, including continuous maintenance standards, are available online in pdf format. Major envelope, mechanical, lighting, and modeling addenda that will be incorporated into 90. Oct 08, 2015 welcome to the leviton blog green ashrae standard 90. Documents ashrae 15 safety standard for refrigeration systems. Ashrae standard 152010 safety standard for refrigeration.
Standard 151994, safety code for mechanical refrigeration standard 152001. The standard is recognized by equipment manufacturers, engineers, and contractors as the main guide for personal safety involving refrigeration systems. The ashrae datacom series includes publications which provide a comprehensive treatment of datacom cooling and related subjects. Instead, it refers to ashrae standard 34 2010 which identifies safety classifications and refrigerant concentration limit rcl for refrigerants. All 109 addenda processed by ashrae in the creation of standard 90. February 2012 errata to standard 116 2010 methods of testing for rating seasonal efficiency of unitary air conditioners and heat pumps ansi approved. In order to move the industry forward toward more energy efficient design, ashrae is making it easier for facility professionals to access the flagship energy standard, 90. Ashrae standard 15 applied to packaged, split and vrf systems.
Ashrae standard 15 2010 establishes safeguards for life, limb, health. Ansi ashrae standard 55 2010 is the latest edition of standard 55. Ansiashrae 152010 safety standard for refrigeration systems. This standard is directed toward the safety of persons and property on or near the premises where refr. Describe the changes to ashrae standard 15 that are under. Standard 152010, safety standard for refrigeration systems standard. Specific information on the contents of each addendum.
The standard outlines conditions for environmental thermal acceptability. Ashrae 15 interpretation june 27, 2010 37 example 4 background january 30, 2011 38. Its important to remember that standard 15 applies to more than large chillers. For the purposes of this website, requirements of standard 62. Ashrae standards now available as online download offerings from icc. The standard outlines conditions in which a specified fraction of the occupants will find the environment thermally acceptable. The only way they will work is if you click the link within the ashrae website. Ansi ashrae standard 15 2010, safety standard for refrigeration. Course materials originally published by the doe building energy codes program, april, 2011.
The mechanical ventilation required to exhaust an accumulation of refrigerant due to leaks of a rupture of the system will be capable or removing air from the machinery room in not less than the following quantity. Ventilation requirements for refrigerating machinery rooms. Ashrae 81 astm 21 bs 5 csa 8 iec 2 ul 4 publication year. Mick schwedler, susanna hanson, mike patterson, matthew bye, what the viewer can expect to learn. Ansiashrae 152010 and ansiashrae 342010 package safety. Department of energy under contract deac0576rl01830.
Ansiashrae 152010 safety standard for refrigeration. Ansiashrae 552010 thermal environmental conditions for. Ashrae standard 152010 establishes safeguards for life, limb, health, and property. Foreword ashrae standard 342010 revised the toxicity classification definition to use occupational exposure limit oel in place of threshold limit valuetimeweighted average tlvtwa and. The current version of the standard does not address the safety of any particular refrigerant. Ansiashrae 15 2010 safety standard for refrigeration systems and standard 342010 designation and classification of.